Rm-materials-handling VARIABLE SPEED CONTROLS ControlMaster NXT Service User Manual Page 28

  • Download
  • Add to my manuals
  • Print
  • Page
    / 53
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 27
R&M Materials Handling, Inc.
4501 Gateway Boulevard
Springfield, Ohio 45502
P.: (937) 328-5100
FAX: (937) 325
-
5319
28/53
R&M Materials Handling, I
5.2.7 S3 Acceleration and deceleration ramp times in traveling movement application
This switch group adjusts the ramp time for motor acceleration and deceleration. The ramp time is defined as from
zero to the set maximum frequency. The acceleration and deceleration times are the same.
Contact the product’s manufacturer, if it is necessary to recalculate the ramp time.
Note: The ramp time must be set according to the wiring diagrams and parameter lists and it shall not be shortened.
Decreasing the ramp time may damage the motor brakes or the frequency converter. The ramp time can be increased, if
necessary.
Switch S3
Acceleration and
deceleration ramp time
-1 -2 -3
1 1 0 1.5
0 1 1 2
0 1 0 2.5
1 0 1 3
0 0 0 3.5
1 0 0 4
0 0 1 4.5
1 1 1 5.5
Page view 27
1 2 ... 23 24 25 26 27 28 29 30 31 32 33 ... 52 53

Comments to this Manuals